Spray Characterisation
As part of our fluid mechanics activities we offer spray characterisation
services which we carry out either at the customers site or within our own
laboratory. This type of work is carried out using in-house instrumentation
like the Malvern and Phase Doppler Particle sizing systems. Our Phase
Doppler system is mounted on a 3D traversing system which allows for a fully
automated mapping of sprays. We can also deal with mapping transient sprays
such as those generated by medical inhalators. Laser light sheet is also
another technique which we frequently use to obtain various spray
characteristics like spray cone angle and density.
During the last years our services in this area were in:
- Inlet fog boost in industrial gas turbines
- Performance studies of spray nozzles
- Routine evaluation of Aerospace fuel nozzles
- Fuel spray placement studies during ignition
- Fuel spray studies in a cross flow for CFD validation
- Automated optical spray cone angle measurement device
 |
| Light sheet spray
section |
 |
| Volume flux of a
spray in cross flow |
|
|
|
PDA in spray
|
|
|
Light sheet visualisation of spray in cross flow
|
|